Analisis Efisiensi Heating System Pada Kumbung Jamur Merang Dengan Variasi Pengkondisian Temperatur Air

Sagita, Rifa Ariviani (2024) Analisis Efisiensi Heating System Pada Kumbung Jamur Merang Dengan Variasi Pengkondisian Temperatur Air. Sarjana (S1) thesis, Universitas Islam 45 Bekasi.

[thumbnail of PENDAHULUAN.pdf] Text
PENDAHULUAN.pdf

Download (791kB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf
Restricted to Repository staff only

Download (102kB) | Request a copy
[thumbnail of BAB II.pdf] Text
BAB II.pdf
Restricted to Repository staff only

Download (322kB) | Request a copy
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Repository staff only

Download (858kB) | Request a copy
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (335kB) | Request a copy
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Repository staff only

Download (27kB) | Request a copy
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf

Download (85kB)

Abstract

Straw mushrooms have an optimal temperature of 31°C - 35°C, and relative
humidity for straw mushrooms is in the range of 85% - 95%. Therefore, the
temperature and humidity of the air around the kumbung is considered to be very
fluctuating, so efforts are needed to maintain the temperature and humidity. In this
test, a heating system was used. The heating system uses 3 variations, namely water
temperature 50°C, water temperature 60°C, water temperature 70°C. The heating
system used in this research uses a single-burner stove and is fueled by gas which
aims to produce hot water and then it will flow into the mushroom kumbung via a
hose and the water will be sprayed using a spray every 5 minutes for 24 hours. The
aim of this research is to determine the heating system process at each temperature
condition used, determine the heat transfer produced during each process, and
determine the comparison of total efficiency and overall process efficiency. From
the test results, the Qheating value was 683 W. The heat produced in each process
is that at 50°C conditions we get Qgas = 4 kJ/s, Qair = 3.8 kJ/s, Qspary = 3.2 kJ/s,
at 60°C conditions we get Qgas = 6.3 kJ /s. Qair = 6.1 kJ/s, Qspray = 5.4 kJ/s, at
70°C conditions obtained Qgas = 9.2 kJ/s, Qair = 8.7 kJ/s, Qspray = 7.6 kJ/s . The
most optimal results for the heating system process for mushroom barns at 50°C
conditions produce a greater effect on mushroom barns compared to water
conditions of 60°C and 70°C. The total efficiency and overall process efficiency of
the conditioning heating system is that at 50°C the total efficiency is 17% and the
overall process efficiency is 16%; at 60°C conditions the total efficiency is 11%
and the overall process efficiency is 10%; and under conditions of 70°C the total
efficiency is 7.4% and the overall process efficiency is 7.7%.

Item Type: Thesis (TA, Skripsi, Tesis, Disertasi) (Sarjana (S1))
Contributors/Dosen Pembimbing,NIDN Dosen bisa diakses di LINK https://bit.ly/NIDNdosenunismabekasi:
Contribution
Contributors / Dosen Pembimbing
NIDN
UNSPECIFIED
Rahmanto, R. Hengki
45101032013007
UNSPECIFIED
Paridawati, Paridawati
45114082009024
Keywords / Kata Kunci: Heating System, Heat Transfer, Efficiency, Comparison
Subjects: Konversi Energi
Faculty: Fakultas Teknik > Teknik Mesin S1
Depositing User: Ms Rifa Ariviani Sagita
Date Deposited: 28 Jun 2024 04:08
Last Modified: 28 Jun 2024 04:08
URI: http://repository.umindonesia.ac.id/id/eprint/5440

Actions (login required)

View Item View Item